Part Number Hot Search : 
ASI10578 CY8C2 26705VUQ SMBJ40 T5551 SKY13 TORX180 2SK334
Product Description
Full Text Search
 

To Download CINT3110 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  CINT3110 110w triple output industrial series www.slpower.com CINT3110 rev 1.1, 26-nov-12 1 features ? 2? x 4? x 1.3? package ? suitable for 1u applications ? 110w w/air, 80w convection cooled ? universal input 90-264vac ? efficiency 87% typical ? approved to csa/en/iec/ul60950-1, 2 nd edition ? power fail signal ? remote sense ? 3 year warranty ? rohs compliant description the CINT3110 series are industrial grade, high efficiency, triple output power supplies in a small 2? x 4? size. the CINT3110 family is ideal for industrial and ite applications requiring multiple outputs and small footprint. compliant to iec60950-1 2 nd edition, the CINT3110 models feature outputs of 5/12v, 5/15v, 5/24v, includes a power fail/dc ok signal, and meet class b conducted emi. model selection model output current ** ripple & total ovp number volts * w/200lfm air convection noise** * regulation threshold CINT3110a0508k01 v1 5v 14.0a 10.0a 1.0% pk-pk ? 2% 7.5v max. v2 12v 6.0a 4.5a 1.0% pk-pk ? 3% 115%-135% v3 -12v 1.0a 1.0a 2.0% pk-pk ? 10% 115%-135% CINT3110a1708k01 v1 5v 14.0a 10.0a 1.0% pk-pk ? 2% 7.5v max. v2 15v 4.5a 3.5a 1.0% pk-pk ? 3% 115%-135% v3 -15v 1.0a 1.0a 2.0% pk-pk ? 10% 115%-135% CINT3110a1908k01 v1 5v 12.0a 8.0a 1.0% pk-pk ? 2% 7.5v max. v2 24v 4.0a 3.0a 1.0% pk-pk ? 3% 115%-135% v3 -24v 1.0a 1.0a 2.0% pk-pk ? 10% 115%-135% notes: * 5v output is adjustable with +/-10% range ** total convection power is 80 watts. * * * m e a s u r e d w i t h n o i s e p r o b e d i r e c t l y a c r o s s o u t p u t t e r m i n a l s , a n d l o a d t e r m i n a t e d w i t h 0 . 1 f c e r a m i c a n d 1 0 f l o w e s r c a p a c i t o r s . r i p p l e & n o i s e o f v 2 a t no load is 2% maximum. general specifications ac input 100-240vac, 10%, 47-63hz, 1 ? 120?370vdc turn on time less than 2 sec. @115vac (inversely proportional to input voltage and thermistor temperature) input current 115vac: 1.5a, 230vac: 0.75a hold-up time 16ms typical at 110w, 120vac input
CINT3110 110w triple output industrial series www.slpower.com CINT3110 rev 1.1, 26-nov-12 2 general specifications (continued) inrush current 264vac, cold start: will not exceed 45a signals ac power fail, dc ok input fuses f1, f2: 2.5a, 250vac fuses provided on all models overload protection 150%-300% above rating for v2 & v3, 110%- 200% for v1. hiccup mode earth leakage current < 2 9 0 a @ 2 6 4 v a c , 6 0 h z , n c short circuit protection provided - no damage will occur if the output is shorted. efficiency 87% typical at 230vac overvoltage protection see models chart for trip range. output power 110w continuous with 200 lfm airflow, 80w convection cooled ? see chart for specific voltage model ratings. switching frequency pfc: 75khz typical transient response 500s typ. for return to within 0.5% of nominal, 50% load step. ? i/ ? t < 0 . 2 a / s . max volt deviation = 3% isolation input-output: 4000vac input-ground: 1800vac output-ground: 500vac ripple and noise see models chart operating temperature -10c to +70c output voltage see models chart temperature derating derate output power linearly above 50c to 50% at 70c voltage adjustability +/-10% from nominal on 5v output storage temperature -40c to +85c minimum load not required altitude operating: -500 to 10,000 ft. non-operating: -500 to 40,000 ft. total regulation see models chart relative humidity 5% to 95%, non-condensing vibration operating: 0.003g 2 /hz, 1.5grms overall, 3 axes, 10 min/axis non-operating: 0.026g 2 /hz, 5.0grms overall, 3 axes, 1 hr/axis shock operating: half-sine, 20gpk, 10ms, 3 axes, 6 shocks total non-operating: half-sine, 40 gpk, 10 ms, 3 axes, 6 shocks total dimensions w: 2.0? x l: 4.0? x h: 1.3? safety standards en/csa/ul/iec 60950-1, 2 nd edition weight 200g mtbf 245,000 hours, 25 c ambient, 110vac input auxiliary signals ac power fail: during normal operation, stays high. signal goes low with at least 6ms warning before loss of dc output from ac failure. dc ok: open collector logic signal goes and stays high 100ms to 500ms after main output reaches regulation. remote sense: (5v output, optional) will compensate for 0.5v drop min. will operate without remote sense connected. reverse connection protected. notes: 1. specifications are for convection rating at factory settings at 115 vac input, 25c ambient unless otherwise stated. 2. for dc input an external dc safety rated fuse must be used.
CINT3110 110w triple output industrial series www.slpower.com CINT3110 rev 1.1, 26-nov-12 3 emi/emc compliance conducted emissions en55011/22 class b, fcc part 15, subpart b, class b radiated emissions en55011/22 class a; fcc part 15, subpart a, class a static discharge immunity en61000-4-2, criteria a, 6kv contact discharge, 8kv air discharge radiated rf immunity en61000-4-3, 3v/m. criteria a eft/burst immunity en61000-4-4, 2kv/5khz, criteria a line surge immunity en61000-4-5, 1kv differential, 2kv common-mode, criteria a conducted rf immunity en61000-4-6, 3vrms, criteria a power frequency magnetic field immunity en61000-4-8, 3a/m, criteria a voltage dip immunity en61000-4-11, 0% vin, 0.5cycle; 40% vin, 5 cycles; 70% vin, 25 cycles; criteria a line harmonic emissions en61000-3-2, class a, b, c, & d flicker test en61000-3-3, complies (dmax<6%) mechanical drawing notes: 1. all dimensions in inches (mm), tolerance is .02?. 2. mounting holes should be grounded for emi purpose 3. mounting j101 is safety ground connection 4. this power supply requires mounting on metal standoffs 0.20? (5 m) in height.
CINT3110 110w triple output industrial series www.slpower.com CINT3110 rev 1.1, 26-nov-12 4 connector information input connector j100 ground j101 dc output connector j200 signal connector j300 pin 1) ac neutral pin 2) empty pin 3) ac line 0.187? faston tab pin 1) +v1 pin 4) gnd pin 7) v2 pin 2) +v1 pin 5) gnd pin 8) v3 pin 3) gnd pin 6) gnd pin 1) power fail/dc ok pin 2) gnd pin 3) +remote sense pin 4) ?remote sense mating connector: molex 09-50-3031 pins= 08-52-0072 mating connector: molex 01-90020001 mating connector: jst vhr-8n pins = svh-21t-p1.1 mating connector: molex 51065-0400 pins = 50212-8100 isolation specifications parameter conditions/description min nom max units insulation safety rating input/ground input/output output/ground basic reinforced operational electric strength test voltage input/ground input/output output/ground 1800 4000 500 - - vac vac vac leakage current parameter conditions/description max earth leakage current normal condition (nc) single fault condition (sfc) 290a 420a touch current normal condition (nc) single fault condition (sfc) 90a 170a input specifications all specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted. parameter conditions/description min nom max units input voltage 90 115/230 264 vac input frequency 47 50/60 63 hz input current 115vac/max load 1.5 a input current 230vac/max load 0.75 a inrush current 264vac, cold start, 25 c - - 45 a efficiency v i nom , i o nom CINT3110a0508k01 CINT3110a1708k01 CINT3110a1908k01 - 87% - % output specifications parameter conditions/description min nom max units output current v1 output current v2 output current v3 CINT3110a0508k01 0 0 0 10.0 4.5 1 14.0 6.0 1 adc output current v1 output current v2 output current v3 CINT3110a1708k01 0 0 0 10.0 3.5 1 14.0 4.5 1 adc output current v1 output current v2 output current v3 CINT3110a1908k01 0 0 0 8.0 3.0 1 12.0 4.0 1 adc
CINT3110 110w triple output industrial series www.slpower.com CINT3110 rev 1.1, 26-nov-12 5 output specifications (continued) parameter conditions/description min nom max units static line regulation v1 v i min- v i max, v i nom , 0-100% i o1 max -2 - 2 % v o nom static line regulation v2 v i min- v i max, v i nom , 0-100% i o2 max -3 - 3 % v o nom static line regulation v3 v i min- v i max, v i nom , 0-100% i o3 max -10 - 10 % v o nom static load regulation v1 (droop characteristic) v i min- v i max, v i nom , 0-100% i o1 max -2 - 2 % v o nom static load regulation v2 (droop characteristic) vi min-vi max, vi nom, 0-100% io2 max -3 - 3 % vo nom static load regulation v3 (droop characteristic) vi min-vi max, vi nom, 0-100% io3 max -10 - 10 % vo nom hold-up time vin = 120vac, p o = 110w 16 - - ms dynamic load regulation v1, v2, v3 l o a d c h a n g e = 5 0 % , d i / d t = 0 . 2 a / s 0 3 % vo nom start-up time v in = 115vac , i o nom 0 - 2 s ripple & noise v1 20mhz bandwidth 0 1% % vo nom ripple & noise v2 20mhz bandwidth 0 1% % vo nom ripple & noise v3 20mhz bandwidth 0 2% % vo nom protection all specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted. parameter conditions/description min nom max units input fuse t2.5a/250v internal fuse in both line & neutral not user accessible input transient protection 2kv(cm) and 1kv(dm) surge 2 kv (cm) short circuit protection hiccup mode overload protection hiccup mode overvoltage protection latching type, recycle ac input to reset see models chart for trip ranges characteristic curves (note: all waveforms below are based on CINT3110a0508k01 model) output vs. temperature 80w convection cooled and 110w continuous with 200 lfm airflow. derate output power to 50% at 70 ? c. 0 20 40 60 80 100 120 -10 0 10 20 30 40 50 60 70 o u t p u t p o w e r ( w ) temperature ( c) convection 200lfm cooling
CINT3110 110w triple output industrial series www.slpower.com CINT3110 rev 1.1, 26-nov-12 6 ripple & noise to verify that the output ripple and noise does not exceed the level specified in the product specification. measured using a scope probe socket with 0.1f ceramic and a 10f electrolytic capacitor connected in parallel across it, bw limit with 20mhz. output transient response v1 5 0 % l o a d s t e p w i t h i n t h e r e g u l a t i o n l i m i t s o f m i n i m u m a n d m a x i m u m l o a d , d i / d t < 0 . 2 a / s e c . r e c o v e r y t i m e n o t s p e c i f i e d a s t h e r e i s n o l a p s i n r e g u l a t i o n with a 50% load step. maximum voltage deviation is 3%. output transient response v2 5 0 % l o a d s t e p w i t h i n t h e r e g u l a t i o n l i m i t s o f m i n i m u m a n d m a x i m u m l o a d , d i / d t < 0 . 2 a / s e c . r e c o v e r y t i m e n o t s p e c i f i e d a s t h e r e i s n o l a p s i n r e g u l a t i o n with a 50% load step. maximum voltage deviation is 3%.
CINT3110 110w triple output industrial series www.slpower.com CINT3110 rev 1.1, 26-nov-12 7 output transient response v3 5 0 % l o a d s t e p w i t h i n t h e r e g u l a t i o n l i m i t s o f m i n i m u m a n d m a x i m u m l o a d , d i / d t < 0 . 2 a / s e c . r e c o v e r y t i m e n o t s p e c i f i e d a s t h e r e i s n o l a p s i n r e g u l a t i o n with a 50% load step. maximum voltage deviation is 3%. output overload characteristic v1 supply shall protect itself against overload conditions. the power supply shall recover from overload conditions without operator intervention. output overload characteristic v2
CINT3110 110w triple output industrial series www.slpower.com CINT3110 rev 1.1, 26-nov-12 8 output overload characteristic v3 output short circuit characteristic v1 supply shall protect itself against short circuit conditions. the power supply shall recover from short circuit conditions without operator intervention. output short circuit characteristic v2
CINT3110 110w triple output industrial series www.slpower.com CINT3110 rev 1.1, 26-nov-12 9 output short circuit characteristic v3 output overvoltage characteristic v1 supply shall protect itself against over voltage conditions. the power supply shall latch and require ac input recycle to reset. ac input 90v 60hz ac input 264v 50hz output overvoltage characteristic v2
CINT3110 110w triple output industrial series www.slpower.com CINT3110 rev 1.1, 26-nov-12 10 output overvoltage characteristic v3 startup time hold-up time start up time is <2seconds hold up time is 16ms minimum power fail signal timing active low ttl logic signal goes high 100 - 500 ms after main output; it goes low at least 6 ms before loss of regulation. data sheet ? 2012 sl power electronics corp. the information and specifications contained herein are believed to be correct at the time of publication. however, sl power accepts no responsibility for consequences arising from reproduction errors or inaccuracies. specifications are subject to change without notice.


▲Up To Search▲   

 
Price & Availability of CINT3110

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]